CLARK-RELIANCE > MEASURING ARE YOUR BOILER DRUM LEVEL INSTRUMENTS UP O TO THE LATEST ASME CODE REQUIREMENTS BY JAMES W. KOLBUS ver the past 20 years, there have been a number of the specifi ed minimum operating pressure for option B was lowered signifi cant revisions to Section 1 of the ASME Boiler from 900 psi to 400 psi. Prior to 1996, the 900 psi threshold was based and Pressure Vessel Code relating to water level in-on boilers operated with the safety relief valve pressure setting at 900 strumentation. Understanding the timelines associ-psi or greater. In 1996, this was reduced to boilers with a maximum ated with these revisions provides a partial explana-allowable working pressure exceeding 400 psi. However, many opera-tion for the instrumentation that was originally installed on a particular tors and plants require and rely on the continuous use of water gage vintage of boiler by the OEM. Other factors may include instruments glasses at pressures greater than 400 psi to ensure their knowledge that are in addition to those required by the Code and others that have of the water level. A water gage glass is required on all power boilers. been replaced by the user, which may or may not be Code compliant. In 2007, the Code defi ned the application and limitations for Prior to 1991, for operating pressures up to 400 psi, the Code re-the use of magnetic level gages, which consist of a chamber con-quired two water gage glasses or one water gage glass combined with structed with austenitic stainless steel and an internal fl oat that a set of three gage cocks (also known as try cocks, and they are typi-contains a magnet. The fl oat rides vertically in the chamber cor-cally installed on a water column). Gage cocks are valves that vent to responding to the actual water level, while magnetically coupling to an externally mounted indica-the atmosphere and when actuated tor for display of the level. These (by the operator) provide a visual instruments are commonly used confi rmation of steam or water that in the process industry and have emits from the discharge nozzle. In migrated into the boiler indus-1991, the use of gage cocks or a sec-try. However, there are concerns ond water gage glass was eliminated about their application on power from the Code for operating pres-boilers with unpredictable water sures up to 400 psi (Ref: Subsection quality, such as metal particulates PG60.4). This was based on the high that may become lodged onto the reliability of water gage glasses on fl oat and affect it’s buoyancy. these applications. However, some CODE REQUIREMENTS FOR GAGE GLASS PLACEMENT: LEVEL “A” = LOWEST PERMISSIBLE WATER LEVEL, AT WHICH THERE WILL operators still continue to use gage Also, actual operating condi-BE NO DANGER OF OVERHEATING THE VESSEL cocks for confi rmation. tions with a signifi cant reduction A power boiler may be equipped with one of the following op-in pressure compared to the originally specifi ed operating pressure tions for level instruments on boilers with a maximum allowable may result in an inaccurate (higher) level indication, due to chang-es with the specifi c gravity of the boiler water at lower than intended working pressure greater than 400 psi: operating pressures. The Code limits the use of magnetic level gag-• Option A: Two water gage glasses are required, and must es to 900 psi, which greatly reduces the risk for signifi cant indica-tion error. The Code also defi nes the grades of austenitic stainless be viewed from the control area. • Option B: One water gage glass combined with two indepen-steels that may be used for the construction of these instruments. Additional Code requirements for the use of magnetic level gages dent level transmitters. This is most commonly applied. include the rules for the external indicating scale, which must follow Option A is not practical for most modern plants, due to the loca-the same requirements as water gage glasses regarding the location tion of the control area in relationship to the boiler drum(s). In 1996, of upper and lower indication range, without intersecting the ves-? 8 TO D A Y ’ S B O I L E R FA L L 2 0 11
Are Your Boiler Drum Level Instruments Measuring Up To The Latest ASME Code Requirements?
James W. Kolbus
Over the past 20 years, there have been a number of significant revisions to Section 1 of the ASME Boiler and Pressure Vessel Code relating to water level instrumentation. Understanding the time-lines associated with these revisions provides a partial explanation for the instrumentation that was originally installed on a particular vintage of boiler by the OEM. Other factors may include instruments that are in addition to those required by the Code and others that have been replaced by the user, which may or may not be Code compliant.<br /> <br /> Prior to 1991, for operating pressures up to 400 psi, the Code required two water gage glasses or one water gage glass combined with a set of three gage cocks (also known as try cocks, and they are typically installed on a water column). Gage cocks are valves that vent to the atmosphere and when actuated (by the operator) provide a visual confirmation of steam or water that emits from the discharge nozzle. In 1991, the use of gage cocks or a second water gage glass was eliminated from the Code for operating pressures up to 400 psi (Ref: Subsection PG60.4). This was based on the high reliability of water gage glasses on these applications. However, some operators still continue to use gage cocks for confirmation.<br /> <br /> A power boiler may be equipped with one of the following options for level instruments on boilers with a maximum allowable working pressure greater than 400 psi:<br /> <br /> • Option A: Two water gage glasses are required, and must be viewed from the control area.<br /> <br /> • Option B: One water gage glass combined with two independent level transmitters. This is most commonly applied.<br /> <br /> Option A is not practical for most modern plants, due to the location of the control area in relationship to the boiler drum(s). In 1996, The specified minimum operating pressure for option B was lowered from 900 psi to 400 psi. Prior to 1996, the 900 psi threshold was based on boilers operated with the safety relief valve pressure setting at 900 psi or greater. In 1996, this was reduced to boilers with a maximum allowable working pressure exceeding 400 psi. However, many operators and plants require and rely on the continuous use of water gage glasses at pressures greater than 400 psi to ensure their knowledge of the water level. A water gage glass is required on all power boilers.<br /> <br /> In 2007, the Code defined the application and limitations for the use of magnetic level gages, which consist of a chamber constructed with austenitic stainless steel and an internal float that contains a magnet. The float rides vertically in the chamber corresponding to the actual water level, while magnetically coupling to an externally mounted indicator for display of the level. These instruments are commonly used in the process industry and have migrated into the boiler industry. However, there are concerns about their application on power boilers with unpredictable water quality, such as metal particulates that may become lodged onto the float and affect it’s buoyancy.<br /> <br /> Also, actual operating conditions with a significant reduction in pressure compared to the originally specified operating pressure may result in an inaccurate (higher) level indication, due to changes with the specific gravity of the boiler water at lower than intended operating pressures. The Code limits the use of magnetic level gages to 900 psi, which greatly reduces the risk for significant indication error. The Code also defines the grades of austenitic stainless steels that may be used for the construction of these instruments.<br /> <br /> Additional Code requirements for the use of magnetic level gages include the rules for the external indicating scale, which must follow the same requirements as water gage glasses regarding the location of upper and lower indication range, without intersecting the vesSel connections. Also, no external control devices are permitted to be attached. It must be noted that magnetic level gages are an excellent device for a variety of application fluids including feedwater applications, but power boiler applications can be a concern, especially those with poor water treatment.<br /> <br /> In 2008, the use of globe-type isolation valves was added for the isolation applications between a drum and water column or level instrumentation, provided the internal geometry of the valve body is designed with at least ¼ of the inlet bore diameter above the seat in a straight-line path, when the valve is open. This requirement prevents sediment traps or blockage from developing, which could result in a false or trapped level indication. The use of globe-type vs. gate-type valves has become widely accepted and generally providing longer service life on these frequently cycled boiler applications.<br /> <br /> Also in 2008, the Code prohibited the use of structural webs from the internal vision area of transparent water gage glasses. The use of structural webs is common among lighter weight gage glass chamber designs that are commonly applied to process fluids. However, these webs can mask the actual water level and can cause a water indication to be misinterpreted by the operator, when viewing the gage glass from a distance. A properly designed chamber for a water gage glass will be very reliable without structural webs.<br /> <br /> The latest improvement from in the industry to improve the ease of readability of water gage glasses from a great distance is the Clark-Reliance Simpliport 180 Water Gage System, which provides 180 degree viewing of the water level in a ported type water gage glass. Clark-Reliance introduced the Simpliport 180 Gage Glass Viewing system on ported type water gage glasses for any application up to 3,000 psi. This enables the operator to view the water level from virtually any angle. These systems can be installed on any power boiler. See the video at www.Simpliport180.com.<br /> <br /> In summary, we suggest that users consult with their insurance carrier and local state authority for confirmation of the minimum requirements for their boiler because they may exceed the Code with additional instrumentation requirements, in order to be in compliance. Boiler controls continue to be the largest cause for violations during state inspections. The selection, installation, and maintenance of drum level instrumentation must be taken seriously for plant and personnel safety.<br /> <br /> Kolbus is product manager - Clark-Reliance Boiler Trim Products. Reach him at Jkolbus@clark-reliance.com or visit www.clark-reliance.com.
Publication List